News & Topicsイベント案内

Spin-L共催 生理学研究所 感覚認知情報研究部門公開セミナーを8月30日(金)に開催します。

内容

本セミナーでは、スタンフォード大学のZihan Zhou先生より、MRフィンガープリンティング(MRF)という方法を用いた脳計測による研究について講演していただきます。MRFとは、一見ランダムに見えるようなパルスシーケンスから得られたMR計測データからパターン認識の手法を用いることで定量的な脳画像計測データを複合化する手法です。撮像時間が短縮されることから主に小児を対象とした発達脳画像研究への応用が期待されています。

(本セミナーは英語で開催されます)

タイトル

Fast and precise quantitative measures of white matter development with magnetic resonance fingerprinting.

講師

Dr. Zihan Zhou (Stanford University, USA)

Abstract

Developmental cognitive neuroscience aims to shed light on evolving relationships between brain structure and cognitive development. To this end, quantitative methods that reliably measure individual differences in brain tissue properties are fundamental. Standard qualitative MRI sequences are influenced by scan parameters and hardware-related biases, and also lack physical units, making the analysis of individual differences problematic. In contrast, quantitative MRI can measure physical properties of the tissue but with the cost of long scan durations and sensitivity to motion. This poses a critical limitation for studying young children. Here, we examine the reliability and validity of an efficient multiparameter method - Magnetic Resonance Fingerprinting (MRF) - in children scanned longitudinally. We focus on T1 values in white matter, since quantitative T1 values are known to primarily reflect myelin content, a key factor in brain development. Forty-nine children aged 8-13y (mean 10.3y ±1.4) completed two scanning sessions 2-4 months apart. In each session, two 2-minute 3D-MRF scans at 1mm isotropic resolution were collected to evaluate the effect of scan duration on image quality and scan-rescan reliability. A separate calibration scan was used to measure B0 inhomogeneity and correct for bias. We examined the impact of scan time and B0 inhomogeneity correction on scan-rescan reliability of values in white matter, by comparing single 2-min and combined two 2-min scans, with and without B0-correction. Whole-brain voxel-based reliability analysis showed that combining two 2-min MRF scans improved reliability (pearson’s r=0.87) compared with a single 2-min scan (r=0.84), while B0-correction had no effect on reliability in white matter (r=0.86 and 0.83 4-min vs 2-min). Using diffusion tractography, we delineated MRF-derived T1 profiles along major white matter fiber tracts and found similar or higher reliability for T1 from MRF compared to diffusion parameters (based on a 10-minute dMRI scan). Lastly, we found that T1 values in multiple white matter tracts were significantly correlated with age. In sum, MRF-derived T1 values were highly reliable in a longitudinal sample of children and replicated known age effects. Reliability in white matter was improved by longer scan duration but was not affected by B0-correction, making it a quick and straightforward scan to collect. We propose that MRF provides a promising avenue for acquiring quantitative brain metrics in children and patient populations where scan time and motion are of particular concern.

概要

日時 2024年8月30日(金)10:00~11:00
形式 オンライン(Zoom)
参加登録 参加登録はこちらにアクセスください(8月26日締切)
担当者 竹村 浩昌(生理学研究所 感覚認知情報研究部門 教授)